HPE ProLiant ML10 Gen10 Server

HPE ProLiant ML10 Gen10 Server

Regular price Rs. 0.00 Sale

Availability: In Stock Out of Stock

Stock Alert:Click here

Product Type:

SKU: ML30 ML10

The HPE ProLiant ML10 Server is a single-socket 4U tower server. Delivers excellent value in a large form factor that small businesses require to run a small network environment. Features Dual-Core Processor: Intel Pentium G2130 (3.20 GHz/2-core/3MB/55 W, 1600) Processor Integrated...

Enquire Now Click For More Info

The HPE ProLiant ML10 Server is a single-socket 4U tower server. Delivers excellent value in a large form factor that small businesses require to run a small network environment.

  • Dual-Core Processor: Intel Pentium G2130 (3.20 GHz/2-core/3MB/55 W, 1600) Processor
  • Integrated 1 x 3MB Level3 Intel smart cache
  • Intel C204 series chipset
  • HPE Embedded Smart Array B110i SATA RAID Controller (RAID 0/1/10)

Dimensions (H x W x D) (with feet)

14.3 x 6.5 x 15 in (36.39 x 16.5 x 38.1 cm)

Weight (approximate)

Non-Hot Plug LFF Full Loading Single Package weight

9.74 kg (21.45 lb)

Non-Hot Plug LFF Full Loading without Package

7.80kg (17.18 lb)

Non-Hot Plug LFF light Loading without Package

5.94kg (13.08 lb)

300W Input Requirements
(per power supply)

Rated Line Voltage

90 to 140 VAC,
180 to 264 VAC

Rated Input Current

8A (at 100 VAC)
4A (at 200 VAC)

Rated Input Frequency

47 to 63 Hz

Rated Input Power

410W (at 115 VAC),
410W (at 200 VAC)

Power Supply Output
(per power supply)

Rated Steady-State Power

300 W (at 100 VAC),
300 W (at 200 VAC)

Maximum Peak Power

320 W (at 100 VAC),
320 W (at 200 VAC)

System Inlet Temperature

Operating

10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. The maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.
The system may shut down if operating with a fan fault or above 42°C (107.6°F).

Non-operating

-30° to 60°C (-22° to 140°F). The maximum rate of change is 20°C/r (36°F/hr)

Relative Humidity
(non-condensing)

Operating

10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing.

Non-operating

5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.

Altitude

Operating

The maximum allowable altitude change rate is 457 m/min (1500 ft/min).

Non-operating

The maximum allowable altitude change rate is 457 m/min (1500 ft/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Level C (idle 5.6 bel/OP 6.0 bel)

Emissions Classification (EMC)

FCC Rating

Class B

Normative Standards

CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1

 

Part Code

ML10 Gen10

Recently viewed product

You can control fully on this carousel from store admin as describe in above section

Loading...